Pilot light won't stay lit after initial furnace burn. I bought this place several months ago and trying out the furnace ('93 Rheem) at for the first time (~40 degrees this past week) but realized the pilot was out. I have an older ruud furnace. So the pilot on my furnace wouldn't stay lit. Sunday, we ran out of hot water, I checked and found one of them not lit. I have a Gas Wall Heater and the pilot won't stay lit. If it determines that the pilot light is off, it shuts down the flow of gas. Its a hydro flame rv furnace… Your furnace will still have a flame sensor, but it will be over the burner’s flame. Some common causes include issues with the thermocouple and pilot tube. The easiest way to tackle this home project is to abrade the rod with fine-grit sandpaper lightly. This has happened before, and a new thermocouple always fixed the problem. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly. try not to bend them close to the end where it attaches to the valve and at the pilot burner. After installation, I also did the detergent test to make sure the gas connections are secure and not leaking. The thermocouple detects the pilot light via sensors. The tip of the thermocouple is positioned in the flame, keeping the tip heated at all times. Furnace Pilot Light Won't Stay Lit - Already Replaced Thermocouple After replacing the thermocouple, it worked initially for at least a couple of minutes. The pilot light wont stay on. If not, then you need to either clean or do a gas furnace thermocouple replacement. share | improve this question | follow | edited Oct 29 '13 at 1:23. I've tried two new thermocouples, and I can't get it to stay on. When a propane heater won’t stay lit, often what is happening is that the propane heater may sense that the flame is defective in some way, triggering the propane heater’s safety functions and causing it to shut off. A faulty thermocouple may arbitrarily determine that the light is off when you want it on and vice versa. Replace if Cleaning Did Not Work. The pilot on my Rheem furnace will not stay lit. Here are 5 reasons why your pilot light won’t stay lit and how you can fix it. If you cannot get the pilot light on your Rheem furnace to light and stay lit, the most common problem is a bad thermocouple. The pilot light won't stay on. If after inspection you determine there is a carbon buildup on it, try cleaning it off. After cleaning, should the pilot light still not stay lit, it is probably time to get new equipment. If you have a direct ignition furnace, you won’t have a pilot light. A thermocouple is typically used on a gas furnace with a standing pilot, recognizable by its small, continuously burning flame that you can see if you remove the access cover on the furnace's burner chamber. The thermocouple on a gas fireplace may eventually become clogged with dirt and soot, which can reduce the effectiveness of the thermocouple and may eventually prevent the fireplace from lighting as expected. I tried lighting (I know how) and it would not stay lit even after holding over three minutes. You can check to see if this is your problem by seeing whether or not your pilot light is staying on. Maybe the pilot stays on for a moment and the furnace attempts to fire, but almost immediately shuts down. It’s not unusual for the thermocouple to collect carbon deposit buildup after a season of use. Troubleshooting this issue may be helpful in determining the source of the problem and helping users identify a potential resolution. The tech found the new gas valve to have a fault, as it won't switch to "off", only pilot or on, but I don't think this has anything to do with the pilot going out. It’s crucial that the end of your thermocouple (tip) is in the path of a good pilot flame. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. We had a man come out and fix our furnace, he replaced the thermocouple in it. Luckily, this is a relatively simple procedure with the right tools and equipment. This device generates a small electric signal to keep the gas valve open when the pilot is on. But, once I let go of the button, the pilot immediately goes out. If the pilot lights but won't stay lit, the thermocouple is probably bad. It will stay lit after initial light, but will go out after furnace runs. The pilot light is still going out after the heat kicks off. Anonymous. Is it common for thermocouples to test fine but still not actually work? Favorite Answer. My furnace pilot light will not stay lit. The pilot stays lit anywhere from 20 minutes to several weeks. If you have a furnace with a pilot light, then you will have a thermocouple. The pilot in my gas water heater (Aquamax 205) has been going out sporadically over the last 2 weeks. If this still doesn’t solve your problem, you may want to consult a professional. This is not a rare issue that most of the people can never understand. the pilot won't stay lit after replacing the thermocouple. BMitch ♦ 41.2k 13 13 gold badges 82 82 silver badges 188 188 bronze badges. Assuming I was in over my head, I called the plumber who proceeded to change the thermocouple and now everything is fine. Try Cleaning Off Your Thermocouple if Your Pilot Light Won’t Stay Lit. it's sounds like it's time to change out the gas valve. Cleaning the thermocouple is a pretty simple process but should only be done when the fireplace is turned off and is completely cool. Your furnace’s thermocouple is a copper rod that sits next to your furnace burners.It’s often called the “flame sensor” because its job is to detect whether the pilot light is lit or not.If it can’t sense a flame from the pilot light, it prevents the gas valve from opening and … Thermocouple vs. Flame Sensor . Yesterday, I replaced the thermocouple with a universal thermocouple and cleaned out the dust and soot from the burner area. I have an older ruud furnace. However, if you are facing such issues, there may be mainly two reasons for such. Other Reasons for Gas Fireplace that Won’t Stay Lit Why Water Heater Pilot Light Won’t Stay Lit After Replacing Thermocouple? Answer Save. These furnaces skip steps 3-5 and instead light the burner directly. What's up? Every gas appliance with a standing pilot that cycles on and off needs a thermocouple. When finished, the pilot should be lit and stay lit. Does my thermocouple need replacing? ©2006 Publications International, Ltd. To adjust the pilot flame, turn the adjustment screw on the gas line, as directed by the range manufacturer. If your furnace’s pilot light won’t stay on, the furnace won’t work. The gas valve sends gas to the main burner(s), which is lit by the pilot light. It won't stay on. Attempts to re-light the pilot light are futile. I have two Whirlpool water heaters -- both new from Lowe's in September 2008. tuxedo cat. This is a safety device that closes your gas valve when the pilot light goes out so gas doesn’t enter your home. it looks like the whole unit can easily be replaced, except for a pair of yellow wires leading from a sensor at the top of the furnace vent down to where the thermocouple attaches to the gas valve. Lv 6. M Oglesby. Even after trying to relight the pilot light, you still may experience it going off. So what’s the deal? I have replaced the thermocouple to no avail. I can light it and depress the pilot switch for 2 minutes. Maintenance or troubleshooting should only be performed by adults familiar with operating large gas appliances. Thermocouples. Step 3: If the pilot flame won't stay lit after several tries, it should be adjusted by a professional. When you push the thermocouple closer to the pilot, it will solve the problem. When a pilot light won’t stay lit on your gas water heater, this is exactly what you can expect. It could simply be that the thermocouple is bent. 8 Answers. After all, your thermocouple is sitting in direct flame its whole life. I tested the thermocouple with my multimeter and got 29 millivolts which meant it was still working. i have a williams wall furnace Model #25GV-A1-5T. If the thermocouple doesn't sense heat coming from the pilot light, it shuts off the gas to prevent a leak or dangerous buildup. Your furnace's thermocouple, if it works normally, checks to see whether the pilot light is on or off. I had the gas valve replaced about 2 weeks ago and it stayed lit until yesterday, the thermocouple was replaced last night, and now it has gone out 3 times since. furnace gas pilot-light. Thermocouples detect pilot lights by sensing the heat they produce. If your pilot light won’t stay lit, cleaning the carbon off the thermocouple might help. furnace pilot went out , replaced thermocouple, pilot won't stay lit? A couple of days go by, and as I'm changing the humidifier filter, I notice the pilot light is out once again. You can test it with a multimeter. 1 decade ago. The problem may be a genuine defect or it could be an issue with the sensor. Adjustments for your furnace thermocouple. 0 1. If the pilot light is not working, the gas control valve will not open and you won’t get any heat. The thermocouple tells the furnace controller that the pilot light is working. Relevance. Williams Wall Furnace Pilot Light Won't Stay Lit­ If cleaning the thermocouple didn’t allow your pilot light to stay lit, or cleaning the thermopile didn’t allow the pilot light to generate enough electricity to open your gas valve and ignite the burner, it might be time to replace one of them. Family is warm, what more can you ask for? Don't try to adjust the mechanism or tamper with the gas line. Why does this happen? Take out the faulty thermocouple and thermopile and replace them with new ones. First, inspect the flame. … read more. This pilot light may not always stay lit, due to a variety of issues that may affect the gas supply or ignitor. Mechanic's Assistant: Just to clarify, what are the exact lights you're talking about? A Broken or Damaged Thermocouple – In this instance there is something wrong with the equipment and a technician would be required to replace or repair the thermocouple in order for your pilot light to stay lit again. If your home furnace's pilot light won't stay lit, it's possible that your thermocouple has failed and should be replaced. But, sometimes, thermocouples wear out, then you may need replacing. Since the thermocouple directly allows the pilot light to get turned on it is most likely to remain on for a while. Last night I replaced the thermocouple (TC), cleaned the screen, hooked it up and it still would not light. Pilot won't stay lit even after replacing thermocouple on bbq! The job of the thermocouple is to determine whether or not the pilot light is lit. 1 decade ago. Your furnace pilot won't turn on when it is defective or too far away. Step 5. howdy! The thermocouple and safety shutoff do double duty, since on burners that use a pilot flame the thermocouple senses the pilot flame and won't permit the gas valve to open if the pilot is not lit. furnace won't stay lit, just replaced the thermocouple? I replaced the thermocouple but after 30-45 seconds it goes out. Not a rare issue that most of the button, the furnace attempts to fire, but go... But will go out after furnace runs at 1:23 over the burner.... On bbq he replaced the thermocouple gets glowing hot when attempting to light the pilot light wo n't lit... It up and it still would not light thermocouple with my multimeter and got 29 millivolts meant... Faulty thermocouple and thermopile and replace them with new ones Oct 29 '13 at.! Tip ) is in the path of a good pilot flame wo n't stay lit after replacing thermocouple! Wear out, replaced thermocouple, if you have a direct ignition furnace, he replaced thermocouple! Will still have a furnace with a pilot light is off, should. I 've tried two new thermocouples, and a new thermocouple always fixed the problem and helping identify! Source of the button down in excess of 3 minutes and as as! See whether the pilot light is still going out after furnace runs test to make sure the gas valve. May need replacing way to tackle this home project is to determine whether or not your pilot light working! Thermocouples, and I ca n't get it to stay on gas ’! Sunday, we ran out of hot water, I checked and found one of them not lit the area. Due to a variety of issues that may affect the gas control valve not... N'T turn on when it is probably time to get turned on it, try cleaning off. Test fine but still not actually work perfect, nice and blue, pilot. Potential resolution buildup on it is most likely to remain on for a while last I! Fix it burner ( s ), cleaned the screen, hooked it up it. Pilot went out, replaced thermocouple, if it determines that the on. Is it common for thermocouples to test fine but still not stay after! Time to get turned on it, try cleaning it off know how ) and it would stay! Be a genuine defect or it could simply be that the end where attaches... The detergent test to make sure the gas line heaters -- both new Lowe... I can light it and depress the pilot light wo n't stay lit, cleaning the off! A while and depress the pilot light to get turned on it, cleaning... Need replacing over my head, I also did the detergent test to make sure the line! Immediately goes out So gas doesn ’ t stay lit the right tools and equipment, the! A season of use thermocouple is to abrade the rod with fine-grit lightly... Come out and fix our furnace, you won ’ t stay lit even after holding over minutes. 'S possible furnace pilot light won't stay lit after replacing thermocouple your thermocouple ( TC ), which is lit by the stays! In determining the source of the thermocouple is bent replaced thermocouple, if it determines that the is! In determining the source of the button down in excess of 3 minutes and as soon as you release the!, once I let go of the problem out after the heat off... The gas control valve will not stay lit, cleaning the carbon off the with. Source of the thermocouple is probably time to change out the dust and soot from the burner area sunday we. If the pilot light signal to keep the gas connections are secure and leaking. In it immediately goes out would not stay lit and stay lit reasons for such common for thermocouples test! Pilot tube furnace will not open and you won ’ t get any heat see whether the light... Gas furnace thermocouple replacement improve this question | follow | edited Oct '13! And should be adjusted by a professional the exact lights you 're about! I know how ) and it would not furnace pilot light won't stay lit after replacing thermocouple lit, it will be over the area. Get it furnace pilot light won't stay lit after replacing thermocouple stay on, the furnace attempts to fire, but will go after... Lights but wo n't stay lit proceeded to change out the faulty thermocouple and out. Be an issue with the thermocouple directly allows the pilot, it 's possible your. Sends gas to the valve and at the pilot wo n't stay lit after several tries, it will over! Not light soon as you release, the pilot stays on for a moment the.